Allen-Bradley Dashboard: Live Logix Tags Over EtherNet/IP
Type the controller's IP and a tag name exactly as it appears in Studio 5000, and the value is on your canvas. No FactoryTalk View licence, no OPC server, no code.
Basic is free forever and runs fully offline on one Windows PC.
Illustrative example. Your inputs, your own layout.
Coverage
What SignalStream Studio reads over EtherNet/IP
- ControlLogix and CompactLogix tags by name, controller-scoped or program-scoped (Program:MainProgram.Tag)
- Members of UDTs and array elements by their full path, such as Line1.Speed or Counts[3]
- BOOL, integer, REAL and STRING tags; anything else is shown as text
- Controllers in a chassis, by adding the slot to the IP, such as 10.0.0.5/1
Not supported
- Writing tags. Studio is a read-only monitor.
- Older PLC-5, SLC 500 and MicroLogix controllers that use file addresses (N7:0) instead of tag names.
- Whole structures or arrays as one value. Read each member or element as its own input.
Setup
Set up a EtherNet/IP input in the wizard
A live Test Poll must succeed before Save is enabled, so a wrong address shows up now, not on the floor. Every field is listed in the Data Inputs reference.
- Click Add Input and choose EtherNet/IP.
- Enter the controller's IP address. If the processor is not in slot 0 of its chassis, add the slot, for example 10.0.0.5/2.
- Enter the tag name exactly as in Studio 5000, including Program: for program-scoped tags.
- Click Test Poll. Studio reads the tag live and shows the controller's own error if the name is wrong.
- Optionally scale, clamp or round the value, then save.
- Drag a widget onto the canvas, bind it to the input and hit Publish.
In practice
Example: a CompactLogix palletizer by tag name
A palletizer's CompactLogix exposes Pallet_Count, Layer_Index, Fault_Active and the UDT member Conveyor.Speed. Four inputs, typed exactly as they appear in Studio 5000, give the shift lead a live screen without a FactoryTalk View runtime.
One canvas
Mix EtherNet/IP with your other sources
Rockwell lines often sit beside Siemens or Modbus equipment. Put Logix tags, S7 data blocks and Modbus meters on one canvas, each polling independently, so one controller dropping off the network never freezes the screen.
Remote view
The same dashboard on a phone, laptop or TV
Basic runs the dashboard on the plant PC, fully offline. On Standard and above, the same published dashboard is live in any browser through the Remote Web Dashboard: viewers install nothing, and the values travel over an encrypted connection from the plant PC. The plant PC only connects outbound, so you never open an inbound port, set up port forwarding or run a VPN.
Questions
EtherNet/IP FAQ
Which Allen-Bradley PLCs are supported?
Logix controllers that use tag names: ControlLogix and CompactLogix. Older PLC-5, SLC 500 and MicroLogix controllers with N7:0-style file addresses are not supported.
Do I need FactoryTalk Linx or an OPC server?
No. Studio talks EtherNet/IP (CIP) directly to the controller from the Windows PC. No RSLinx, FactoryTalk Linx or OPC server is involved.
How do I read a program-scoped tag?
Prefix it with the program name, exactly as Studio 5000 shows it: Program:MainProgram.MyTag.
My controller is in slot 2. What do I enter?
Add the slot after the IP with a slash: 10.0.0.5/2. Without a slot, Studio talks to slot 0.
Can it write tags?
No. Studio is read-only by design, so it cannot change anything in a running controller.