Modbus Dashboard: Live Register Values on Any Screen

Point SignalStream Studio at a Modbus TCP device or an RS-485 line, pick a register, and drag it onto a canvas. No gateway, no SCADA project, no code.

Basic is free forever and runs fully offline on one Windows PC.

What SignalStream Studio reads over Modbus

  • Modbus TCP over Ethernet (default port 502) and Modbus RTU over a local COM port (RS-485 or RS-232)
  • All four register types: holding registers, input registers, coils and discrete inputs
  • Any unit / slave ID, so one gateway or RS-485 bus can feed many inputs
  • Holding and input registers as a single 16-bit value, or as a text string spread across several registers with a choice of byte order

Not supported

  • Writing to registers or coils. Studio is a read-only monitor.
  • 32-bit values (floats or long integers) that span two registers. Each input reads one 16-bit register.

Set up a Modbus input in the wizard

A live Test Poll must succeed before Save is enabled, so a wrong address shows up now, not on the floor. Every field is listed in the Data Inputs reference.

  1. Open the editor, click Add Input and choose Modbus TCP, or Modbus RTU for a serial line.
  2. For TCP, enter the device's IP address and port (502 unless your device says otherwise). For RTU, pick the COM port, baud rate, parity and stop bits.
  3. Enter the Unit / Slave ID, choose the register type and type the register address.
  4. Click Test Poll. Studio reads the register and keeps refreshing it every couple of seconds while you work.
  5. Optionally add scaling (y = mx + c), a min/max clamp, a formula or decimal rounding to turn the raw count into engineering units.
  6. Save the input, drag a gauge, number or chart widget onto the canvas, bind it to the input and hit Publish.

Example: a packaging line from three Modbus registers

A filler's line speed sits in holding register 0, its setpoint in register 1, and a 4–20 mA motor temperature transmitter comes in through an analog module as raw counts on input register 12. Scaling turns those counts into °C, a gauge shows speed against setpoint, and a threshold turns the temperature tile amber above 70 °C.

Mix Modbus with your other sources

Modbus is often only half the picture. Put the line's registers next to an OPC UA tag from the packaging PLC, or a shift target pulled from SQL, on the same canvas. Each input polls on its own, so one unreachable Modbus device never freezes the rest of the screen.

The same dashboard on a phone, laptop or TV

Basic runs the dashboard on the plant PC, fully offline. On Standard and above, the same published dashboard is live in any browser through the Remote Web Dashboard: viewers install nothing, and the values travel over an encrypted connection from the plant PC. The plant PC only connects outbound, so you never open an inbound port, set up port forwarding or run a VPN.

Modbus FAQ

Do I type 40001 or 0 as the address?

Type the register's protocol address, which counts from 0. Holding register 40001 in a manual's 1-based notation is address 0 with the register type set to Holding; 40013 is address 12. If a value looks shifted by one register, try the address one lower.

Can it read Modbus RTU over RS-485?

Yes. Choose Modbus RTU in the wizard and select the PC's COM port, which can be a USB-to-RS-485 adapter. Set the baud rate, parity and stop bits to match the bus, then the unit ID of each device you read.

How do I turn a raw register count into engineering units?

Use the scaling step in the wizard. It applies y = mx + c to every reading, so a 0–4000 count from a 4–20 mA card can become 0–100 °C. A formula step is available for anything that isn't linear.

Can I read floating-point values?

Not as a single 32-bit value today. Each input reads one 16-bit register as a whole number (or a string across several registers). Devices that publish a scaled integer, such as temperature × 10, work well with the scaling step.

How often does it poll?

Every 2 seconds by default, and each input polls on its own loop. The live Test Poll in the wizard uses the same cadence, so what you see while configuring is what the dashboard shows.