OPC UA Dashboard: Live Node Values Without a Server Stack
Paste an opc.tcp endpoint, enter a Node ID, and the value is on your canvas. No Grafana, no database, no Node-RED flows to maintain.
Basic is free forever and runs fully offline on one Windows PC.
Illustrative example. Your inputs, your own layout.
Coverage
What SignalStream Studio reads over OPC UA
- Any readable variable node on an OPC UA server, by its Node ID (for example ns=2;s=Line3.Speed)
- Numbers, booleans and strings; other OPC UA types are shown as text
- Anonymous sessions, or a username and password when the server asks for one
- Servers built into PLCs, OPC UA gateways and software servers such as Kepware or Ignition's OPC UA server
Not supported
- Certificate-based Sign or Sign & Encrypt security modes. Use a server endpoint that allows None security, ideally on an isolated OT network.
- Writing node values, calling methods, or alarms and events. Studio reads values only.
Setup
Set up a OPC UA input in the wizard
A live Test Poll must succeed before Save is enabled, so a wrong address shows up now, not on the floor. Every field is listed in the Data Inputs reference.
- Click Add Input and choose OPC UA.
- Enter the server's endpoint URL, such as opc.tcp://192.168.1.20:4840.
- Enter the Node ID of the variable you want, copied from your server's address space browser.
- If the server requires a login, add the username and password. They are stored encrypted on the PC.
- Click Test Poll to see the live value, add any scaling or rounding, then Save.
- Bind the input to a widget and Publish.
In practice
Example: one OPC UA server, every machine on the line
A plant already runs an OPC UA gateway in front of three different PLC brands. Instead of a driver per brand, each tag on the dashboard is one Node ID on that gateway: reject rate, OEE and air pressure share one endpoint.
One canvas
Mix OPC UA with your other sources
OPC UA is a good bridge to equipment you can't reach directly. Mix its nodes with Modbus registers from older devices and MQTT topics from newer sensors, all on one canvas and all polled independently.
Remote view
The same dashboard on a phone, laptop or TV
Basic runs the dashboard on the plant PC, fully offline. On Standard and above, the same published dashboard is live in any browser through the Remote Web Dashboard: viewers install nothing, and the values travel over an encrypted connection from the plant PC. The plant PC only connects outbound, so you never open an inbound port, set up port forwarding or run a VPN.
Questions
OPC UA FAQ
Where do I find a Node ID?
Open the server in any OPC UA browser (UaExpert, or your PLC vendor's tool), select the variable, and copy its NodeId attribute. It looks like ns=2;s=Machine.Speed for string IDs or ns=3;i=1042 for numeric ones.
Does it support OPC UA security modes?
Studio connects with security mode None, either anonymously or with a username and password. Certificate-based Sign and Sign & Encrypt are not supported yet, so use an endpoint configured for None on a network segment you trust.
Can I use it with Kepware, Ignition or a PLC's built-in server?
Any OPC UA server that exposes an endpoint with security None and readable variable nodes works the same way: endpoint URL plus Node ID.
Is this the same as an OPC UA client like UaExpert?
UaExpert is a diagnostic client for engineers. Studio turns chosen nodes into a dashboard for operators and managers: designed once, shown full-screen on the floor and, on Standard, in any browser.
Ready When You Are
Read your first OPC UA value today.
Basic is free, forever, offline. Upgrade only when you need the dashboard off the floor.